PRODUCTS
Burners


COMPONENT PARTS OF LOCAL PRODUCTION EUROPEAN QUALITY AT A REASONABLE PRICE


BURNERS

Gas injection burners ( GIB-1, GIB-2) are used for gathering of heating devices, stoves, water heaters and other similar equipment (using fuel named in the table) for domestic, municipal and industrial purpose:

Fuel type Nominal pressure, Pa
Natural gas State standards 5542 1274+100; 1960+150
Liquidised gas State standards 4047 (State standards 20448-90) 2940+200

Burners for climatic type of areas with moderate and cold climate (category 4.2 St.standards 15150).

Main characteristics and sizes:

Names of characteristics and sizes
Norms for types, GIB
1-2
1-3
1-5
2-5
2-8
2-10
2-12
2-15
2-17
2-20
Nominal heat capacity, kWt, under gas expense: natural, m3/hour, no more than
2,7
3,5
5,5
5,5
8,5
10,5
12,5
15,5
17,5
20,5
0,27
0,35
0,55
0,55
0,85
1,05
1,25
1,55
1,76
2,06
Liquidised, m3/hour, no more than
0,1
0,12
0,2
0,19
--
--
--
--
--
--

BURNER GIB-1 (for convectors)



BURNER GIB-2 (for boilers)


Names of characteristics and sizes
Norms for types, GIB
1-2
1-3
1-5
2-5
2-8
2-10
2-12
2-15
2-17
2-20
Length *, L, mm, no more than
245
350
487
265
265
265
320
400
450
530
Mass, kg, no more than
0,26
0,3
0,35
0,4
0,4
0,4
0,45
0,5
0,55
0,6

* Note. The length of thermocouples can be changed on customer's demand .Exploitation guarantee term - 18 months since putting into operation.

 
Copyright © 2004-2006 Plant "Convector".   Design: Artur Ruschak.   Realization: ALDESIGN WebStudio,    Hosting: AHS