GAS WALL HUNG DOUBLE CIRCUIT BOILERS

Boiler
- is an optimal solving for an individual heating and hot water
supply for your house. Reliable, safe, multifunctional, powerful
and for a reasonable price - this is just what you were looking
for.
European quality of the boiler
- is not just the words. We use the best components of the leading
western European producers:
The most important thing is that high quality
of the boiler

is guaranteed by plant "Convector" - producer N1 of gas convectors
in Ukraine with a net of dealers and service centers throughout
Ukraine.
SUITABLE
FOR A FLAT OR A HOUSE WITH A PIPE OR WITHOUT IT
Boiler
is
suitable for everybody, who needs to heat rooms up to 200 sq.meters
and provide it with hot water. It's good not only for a small
house or an office, but also for a flat in a multistoried building
(even higher than 5-th store). The boiler is produced in two
modifications:
- with an open combustion chamber (flue);
- with a closed combustion chamber (turbo).
ADJUSTED TO OUR CONDITIONS:
Boiler
functions even under conditions of comperatively low gas and
water pressure. Safety and reliability of the boiler is confirmed
by the Certificate of accordance. Safety automatics switches
off the boiler in case of:
THESE FUNCTIONS WILL MAKE YOUR LIFE EASIER AND MORE COMFORTABLE
- Soft start of the boiler - smooth provision of gas,
without any plop;
- No Frost : in case the temperature in a heating curcuit
falls below 5 0Ñ, the control block switches on the pump
in a heating position.
- Antiblocking of the pump: in case the boiler is switched
off, the pump automatically switches on for 10 seconds every
22 hours.
- Stable water temperature .
- Water level and water circulation control in a heating curcuit.
- Smooth temperature regulation in a heating curcuit and hot
water curcuit.
- Ionisation electrode for the burning process control.
- Hydroblock rationally distributes the water streams.
- Windsafe construction.
- Possibility of boiler's immediate switching off manually.
- Water drainage possibility, easy access to the burner, ignition
device , preventive and regulating devices, its taking off and
its placing back without switching off the boiler.
- Observational window.
- Possibility of room thermostate connecting.
| Technical
characteristics of the boiler |
Measuring units
|
Type of the boiler
|
|
23-Â
|
23-Ñ
|
| Combustion chamber |
|
open
|
closed
|
| Nominal heat effect |
êWt
|
23±5%
|
| Coefficient of efficiency, not less than |
%
|
90
|
| Gas expense, no more than |
ì3
per hour
|
2,9
|
| Input nominal pressure of natural gas |
Pa
|
1274+100, 1960+150
|
| Water expense in a hot water curcuit under
t 35 °Ñ |
l / m
|
9
|
| Regulation range of the outlet water temperature: |
|
| in a hot water curcuit |
Ѱ
|
35-60
|
| in a heating curcuit |
Ѱ
|
30-76
|
| Maximum water pressure in a hot water curcuit
|
Bar (kPà)
|
6 (600)
|
| Minimal water pressure in a hot water curcuit
|
Bar (kPà)
|
0,3 (30)
|
| Chimney diameter |
mm
|
130
|
---
|
| Energy consumption, no more than |
Wt
|
120
|
150
|
Overall size, no more than
- width
- depth
- height
|
mm
|
435
325
720
|
435
325
720
|
| Weight |
kg
|
32
|
39
|